30iM Installation
Turn the ice machine to gain access to the rear of the 1.
unit. Remove the access panel by removing the ten
(10) screws (see Figure 6).
Plug the ice machine’s power plug into the outlet on 2.
the drain pump. Place the drain pump in the left, rear
opening of the ice machine with the inlet, vent, and
discharge fittings to the rear of the unit (see Figure 7).
Install 1-3/4 in. x 5/8 in. I.D. inlet tubing to drain 3.
barb on ice machine and then on the inlet of the drain
pump. Clamp both ends of the tube with the large
tubing clamps.
Connect the 18 in. x 3/8 in. I.D. formed vent tube to 4.
the vent on the drain pump and secure with one (1) of
the small tubing clamps.
Route a short section of the 20 ft. x 3/8 in. I.D. tube 5.
through the opening in the access panel and connect
it to the discharge of the drain pump. Secure with the
small tubing clamp.
Route the vent tube and the drain pump power cord 6.
through the remaining openings in the access panel as
shown in Figure 8. Reinstall the panel and secure.
Secure the vent tube to the back of the ice machine 7.
using the supplied tubing clips and screws as shown in
Figure 8.
The vent tube must be attached and secured or water
damage may occur. Make certain there are no kinks in
the tube. The drain pump will not operate correctly with
a partially blocked vent line.
Connect the discharge tube to a suitable drain. Cut 8.
excess tubing as needed. Do NOT allow sags or kinks
in the tubing that will restrict flow.
Make certain that the drain pump is level in the ice 9.
machine’s rear opening.
Plug the power cord of the drain pump into a properly 10.
grounded 115VAC receptacle.
Test the drain pump by slowly pouring water into the 11.
ice machine ice storage bin. Approximately one (1)
quart of water is required to activate the drain pump.
Test the operation of the safety switch by turning the ice 12.
machine on and completely restricting the discharge
line while the pump is operating. Pour more water into
the ice machine’s ice storage bin until the ice machine
turns off. The drain pump will continue to operate.
Remove the discharge tube restriction and allow the
water to be pumped out. The power to the ice ma-
chine will be restored when the water in the pump
returns to normal.
Place the ice machine in the installed location. En-13.
sure that all tubing and power cords are not pinched,
kinked, or disturbed.
Figure 6
Figure 7
Receptacle for
Ice Machine’s Plug
Towards the Rear
of the Ice Machine
To Wall Receptacle
Inlet Tube
Fitting
Discharge
Tube Fitting
Vent Tube
Fitting
Access Panel
Figure 8
Vent Tube
Access Panel
To Drain
OPTIONAL DRAIN PUMP INSTALLATION
6
Screws
Screws
Tubing Clips
Drain Pump’s
Power Cord
Komentáře k této Příručce